Review article Open Access
Simultaneous Determination of Metformin and Pioglitazone in Presence of Metformin Impurity by Different Spectrophotometric and TLC – Densitometric Methods
Amal Khorshid1*, Nessreen S Abdelhamid2, Eglal A Abdelaleem2 and Mahmoud M Amin1
1Analytical Chemistry Department, Faculty of Pharmacy, Nahda University, Egypt
2Analytical Chemistry Department, Faculty of Pharmacy, Beni_Suef University, Egypt
*Corresponding author: Amal Khorshid, Associate professor, Department of Pharmaceutical Analytical Chemistry, Facultly of Pharmacy, Nahda University, Egypt, E-mail: @ or @
Received: May 21, 2018; Accepted: June 21, 2018; Published: June 22, 2018
Citation: Amal K, Nessreen SA, Abdelaleem EA, Amin MM (2018) Simultaneous Determination of Metformin and Pioglitazone in Presence of Metformin Impurity by Different Spectrophotometric and TLC – Densitometric Methods. SOJ Pharm Pharm Sci, 5(3) 1-8. DOI: 10.15226/2374-6866/5/3/00183
Abstract
New simple accurate methods were developed and validated for simultaneous determination of Metformin hydrochloride and Pioglitazone hydrochloride in presence of Metformin impurity Melamine , both in bulk powder and in pharmaceutical preparation using spectrophotometric methods and thin layer chromatography . Method A used zero order spectrophotometric technique for determination of Pioglitazone at 268nm and isoabsorbtive point spectrophotometric technique to determine Metformine at 255 nm in presence of the other drugs and used double divisor technique to determine Metformine in presence of the other drugs at 254 nm. Method B uses TLC densitometric technique for separation and simultaneous determination of the three drugs using toluene / methanol / acetic acid (5:5:0.5) as a developing system and 240nm as a scanning wavelength.

This method were validated and shown to demonstrate good accuracy and precision according to ICH guidelines.

Keywords: Metformin hydrochloride; Pioglitazone hydrochloride; Melamine; Double Divisor and TLC Densitometry;
Introduction
Metformin HCl (MET) is N; N dimethyl imido dicarbonimidic diamide hydrochloride. It is an antidiabitic drug from the biguanide class used in the management of type 2 diabetes. The major action of Metformin is increasing glucose transport across the cell membrane in skeletal muscles [1].

Pioglitazone HCl (PIO) is (±)-5-[p-[2-(5-ethyl-2-pyridyl)- ethoxy] benzyl]-2, 4-thiazolidinedione hydrochloride [2]. It is an anti-diabetic drug from the thiazolidinedione hydrochloride class of drugs [3] MET and PIO combination is impartment for patients suffering from type 2 diabetes who require treatment with more than one anti-hyperglycemic drug to achieve optimal glycemic control [2].

Melamine (MEL) is 1, 3, 5-Triazine-2, 4, 6-triamine; and it is a potential impurity of Metformin. A variety of toxic effects from Melamine, including nephrolithiasis, chronic kidney inflammation and bladder carcinoma.

The literature review show that MET was determined in its bulk powder by liquid chromatography (LC) [4-10] and spectroscopy [11, 12] and capillary electrophoresis [13-15], Pioglitazone was determined by liquid chromatography (LC) [16-19], and capillary electrophoresis [20]. The binary mixture of MET and PIO was determined by some spectrophotometric methods [21-23] and determined by reversed phase liquid chromatography [2, 24-26].

The aim of this work is to develop and validate new analytical methods able to determine the tertiary mixture Metformin, Pioglitazone and Melamine in bulk powder and pharmaceutical dosage form without interference or prior separation.
Experimental
Instruments
Double beam UV_Visible spectrophotometer (SHIMADZU, Japan) .model uv-1601 PC with quartz cell of 1cm path length connected to IBM compatible computer. The software is uv - pc personal spectroscopy version 3.7.

TLC scanner densitometer (Camag, Muttenz, Switzerland). The following requirements were taken into consideration: slit dimensions, 5x0.2 mm; scanning speed, 20 mm/s; spraying rate, 10/mL; data resolution: 100 mm/step. Pre-coated silica gel aluminum plates (20x10 cm; 60 F254) were obtained from Fluka, Sigma-Aldrich Chemie Gmbh, and Germany. The sample applicator for TLC was a Linomat IV with a 100mL syringe (Camag, Muttenz, Switzerland).
Pure standards
Standard MET and PIO with claimed purity of 99.88%and 99.98% respectively according to manufacturer certificate were kindly supplied by Sigma Pharmaceuticals Industries (El Monofeya, Egypt).

Melamine was purchased from sigma Aldrich chemie (Germany) with certified purity of 99.7%.
Pharmaceutical dosage forms
Bioglita plus tablets batch no. [15675] were manufactured by Amoun pharmaceutical Co.SAE (Cairo _ Egypt). Labeled to contain 850 mg of Metformin HCl and 15mg of Pioglitazone HCl.
Solvents and reagents
All reagents and chemicals used were of analytical grade and were used without further purification; they included:

(i) Methanol analar (Central Drug House Ltd., India)
(ii) Toluene and glacial acetic acid (Al-Nasr Pharmaceutical chemicals company, Abu Zaabal cairo – Egypt).
Prepared solutions
Standard stock solutions (1mg/ml)
An amount of 0.025 gm of each drug were accurately weighed into 3 separated 25ml volumetric flask, then the volume in each flask was made up to the mark with methanol.
Standard working solution (100μg/ml)
A volume of 2.5 ml of each stock solution of drugs were diluted to 25ml with methanol in 3 separated 25ml volumetric flasks.
Laboratory prepared mixtures
Mixtures containing different ratios of MET, PIO and MEL were prepared using their standard working solutions in methanol.
Methodology
Linearity and construction of calibration curve
Spectrophotometric method
Different aliquots of PIO, MET and MEL were transferred from working solution (100μg/ml) to three separate series of 10ml volumetric flask and the volume was completed to the mark by methanol to obtained concentration ranges (3μg/ml -25μg/ml), (10μg/ml - 50μg/ml) and (10 μg/ml– 33 μg/ml) from PIO, MET and MEL respectively. The spectrum of each concentration was recorded against methanol as blank. The spectra were observed for selecting of the suitable wavelength for zero order, double divisor and isoabsorptive point.
HPTLC - densitometric method
Into 3 different groups of 10ml volumetric flasks aliquots of MET, PIO and MEL were accurately transferred from their working solution, the volume was then made up with methanol. A 10μl aliquots of each solution was spotted as band of 5mm width on TLC plates to obtain concentration ranges of (3 - 20μg), (3- 12μg) and (0.5 - 5μg) PIO, MET and MEL respectively. The peak area were recorded using a scanning wavelength of 240 nm and calibration curves were constructed by plotting the integrated peak area versus the concentration in μg / band for each compound and the regression equations were computed.
Analysis of laboratory prepared mixtures
Accurate aliquots were transferred from MET, PIO and MEL working solutions into a series of 10ml volumetric flasks completed to volume with methanol and mixed well to obtain tertiary mixtures of different ratios then the absorption spectra of each solution was recorded and the same procedures mentioned under calibration curves were applied in order to determine MET, PIO and MEL in the laboratory prepared mixtures by both spectrophotometric techniques and TLC densitometric method.
Application to pharmaceutical formulation
Bioglita plus tablet are labeled to contain 850 mg MET and 15mg PIO per tablet. The contents of 10 tablets were powdered. An amount of the powder equivalent to 100 mg of MET and PIO were separately transferred into 100ml volumetric flask, 50ml of methanol was added to each of them and sonicated for 30min, cooled and then the volume was completed to mark to obtained 1000 μg /ml of MET and PIO stock solution and then the solution was filtered. Appropriate dilution of the prepared solutions were made to prepare working solutions containing 100 μg / ml of each of PIO and MET and the procedures under construction of calibration curves were followed for both spectrophotometric techniques and TLC densitometric method.
Result and discussion
Spectrophotometric methods
Spectrophotometry is a widely used analytical technique because of its simplicity, low cost and its time consuming
Determination of PIO by zero order
PIO can be determined by zero order spectrophotometry at 268 nm where MET and MEL show no absorbance (Figure 2).

The absorbance spectra of pure PIO solutions of different concentrations (3 - 25 μg / ml) are recorded against methanol as blank (Figure 3).

The calibration curve was constructed relating the absorbance of PIO at 268 nm to concentration (μg / ml) and the regression equation was computed showing a linear relationship (Figure 4).
Figure 1: Chemical structure of (a) Metformin hydrochloride, [b] Pioglitazone hydrochloride and (c) Melamine
Figure 2: Absorption spectra of Metformin 10μg (solid line) , Pioglitazone 10 μg (dashed line) and Melamine (dotted line) 10 μg
Figure 3: The UV absorbance spectra of different concentration (3 – 25 μg/ml) of PIO
Figure 4: Calibration curves relating the absorbance of PIO at 268 nm to the concentration (μg / ml)
Double divisor method ratio spectra for determination of Metformin 254nm
Absorption spectra of pure MET ,different ternary mixture and dosage form solutions were recorded and divided by the standard spectrum of PIO / MEL binary mixture containing 10μg/ml of each and the second derivative of the spectra was obtained (using 4 as delta lamda and 10 as scaling factor) (Figure 5).

A calibration curve relating the peak amplitude of MET at 254 nm to the concentration in μg / ml was constructed and the regression equation was computed showing good linearity in the concentration range of (10 – 45 μg/ ml) (Figure 6 and 7)
Figure 5: The double divisor second derivative spectra of MET , MEL and PIO using (PIO and MEL 10 μg) as divisor
Figure 6: Double divisor second derivative spectra of pure MET (10 – 45 μg /ml) using PIO /MEL (10 μg /ml) as divisor
Figure 7: Calibration curve relating peak amplitude of double divisor second derivative spectra of 4 MET to its concentration in μg /ml.
Isoabsorptive point spectrophotometric method for determination of MET in presence of PIO and MEL
Determination of Metformin at 255nm ( isoabsorptive point ) using methanol as blank
In the isoabsorptive point technique, the concentration of PIO was determined by measuring the absorbance at 268 nm. Then calculate the total mixture concentration by measuring the absorbance at 255 nm. To determine the absorbance of MET we subtract absorbance of the calculated concentration of PIO from the total absorbance of mixture at 255 nm. A calibration curve was constructed relating the absorbance of PIO at 268 nm to concentration (μg / ml) and the regression equation was computed showing a linear relationship (Figure 9).
Figure 8: MET 10 μg (dash line), PIO 10 μg (solid line) and MEL 10 μg (dot line)
Figure 9: Calibration curve relating the peak amplitude of MET at 255 nm to the concentration
Tlc - densitometric method
The TLC densitometric technique was successfully applied for the determination of MET, PIO and MEL in pure form, mixtures and dosage form. This method offers a simple way to quantify directly on TLC plate by measuring the optical density of the separated bands, in order to obtain optimum separation among the studied drugs. Different trials have been carried out to reach the optimum developing system, scanning wavelength, band dimension and slit dimension [27].

Different developing systems with different ratios have been tested such as toluene: methanol, chloroform: methanol and toluene: methanol: acetic acid

The best results concerning chromatographic separation, peak symmetry and linearity were obtained upon using the system (toluene – methanol - acetic (5:5:0.5) by volume). The obtained Rf values were 0.8, 0.2 and 0.5 for PIO, MET and MEL, respectively (Figure 10 and 11).
Figure 10: TLC densitogram of mixture of MET, PIO and MEL.
Figure 11: Calibration curve relating the peak area of TLC peaks of PIO to its concentration in μg / band.
Different scanning wavelength such as 210nm .225nm and 240nm were tried but 240nm was the best scanning wavelength that showed high sensitivity with minimum noise for all the drugs.

Calibration curves were plotted to related the integrated peak area versus the corresponding concentrations in the concentration range of 3-12μg/band, 3-20 μg/band and 0.5 - 5 μg/band for MET, PIO and MEL respectively (Figure 11, 12 and 13). The regression equations were computed and found to be:

AMEL = 3.6831C + 0.0117     R² = 0.9999
AMET = 2.78C - 0.8607          R² = 0.9996
APIO=1.2787C                          R² = 0.9997
Figure 12: Calibration curve relating the peak area of TLC peaks of MET to its concentration in μg / band.
Method validation
Validation of the methods was carried out according to ICH recommendation
Linearity and range
The calibration range of the studied drugs was established through considerations of the practical range necessary according to Beer-lamberts law to give accurate, precise and linear results. Linearity ranges are shown in table [1].

Good linearity is evident from the high values of the correlation coefficient and low values of intercept
Accuracy
Accuracy of the proposed methods was calculated as the percentage recoveries of pure samples of the studied drugs. The concentrations were calculated from the corresponding regression equations and the results are shown in (Table 1).
Precision
Repeatability
Three concentrations (5, 10, 15 μg mL-1 of MET and PIO) were analyzed three times intra-daily using the proposed methods. Good results and acceptable relative standard deviations (RSDs) were obtained (Table 1).
Table 1: Regression and analytical parameters of the proposed zero order, isospestic point, double divisor and TLC –densitometric methods for determination of Metformin, Pioglitazone and Melamine

TLC-densitometric method

Isospestic point

Double divisor

Zero order

Parameters

MEL

MET

PIO

MET

MET

PIO

 

0.5-5µg

3-12µg

3-20µg

10-50µg

10-45µg

3-25µg

Range

3.68

2.7

1.2

0.0107

0.03153

0.0231

Slope

0.019

0.8

0.07

0.0119

-0.0341

0.0207

Intercept

0.9999

0.9996

0.9997

0.9999

0.999903

0.9999

Correlation coefficient

99.33±1.4

100.24±
1.1

100.4 ± 1.09

100.46±0.75

100.168±0.72

99.98±0.68

Accuracy
Mean ±SD

1.45

1.1

1.08

0.756

0.72

0.689

Precision
RepeatabilityA
RSD

 

1.65

1.3

1.17

0.876

0.75

0.731

Intermediate B precision RSD

A The intraday precision (n=3), average of three different concentrations repeated three times within one day.
B The interday precision (n=3), average of three different concentrations repeated three times on three
Intermediate precision
The previous procedure was repeated interdaily on 3 different days for the analysis of the chosen concentration. Good results and acceptable RSD s were obtained.
Selectivity
Selectivity of the proposed analytical method was assessed by the analysis of different synthetic laboratory mixtures contained different ratio of (MET and PIO) within their linearity ranges satisfactory results are shown in table 2.

Specificity of the proposed methods are evident from the spectrophotometric mehods and HPTLC in figure 11which also show no interference between them.
Robustness
The recommended TLC-Densitometric method was found to remain unchanged with small changes in method parameters e.g.: changing acetic acid ratio in the developing system ± 0.02 mL, changing saturation time ± 5 min and changing the scanning wavelength ± 1 nm. Which assessed the robustness of the validated method
System suitability testing parameters
When system suitability testing was done, we obtained acceptable results and the peaks information was given in the resolution (Rs) and selectivity factors (α) values were above 1 and 1.5, respectively, which ensured good separation of each component from the other (Table 4).
Table 2: Determination of Metformin, Pioglitazone and Melamine in laboratory prepared mixtures by the spectrophotometric method

Drugs

pioglitazone

Metformin

Method

Zero order

double divisor

Isospestic point

Mix .no.

Taken

Recovery

Taken

Recovery

Taken

Recovery

1

20

101.8

25

102.1079

20

99.14

2

15

100.3

30

101.8095

25

100.1

3

10

99.8

50

101.2127

30

99.8

4

12

101.6

40

98.7381

40

100.13

5

18

101.4

45

99.05467

45

99.8

6

14

101.94

20

98.5873

50

99.6

Mean ±RSD

101.4±0.83

100.2517±1.63034

99.9±0.5

Table 3: It shows the results of determination of Metformin hydrochloride and Pioglitazone hydrochloride in its pharmaceutical formulations by the spectrophotometric method, proposed TLC - densitometric methods and application of standard addition technique.

Pharmaceutical preparation

TLC

SPECTROPHOTOMETRIC METHODS

ZERO ORDER

ISOSPESTIC

DOUBLE DIVISOR

Bioglita plus

Taken (µg/band)

Found
(%±SD)

Standard addition technique
(mean±SD)

TAKEN
(µg/ml)

FOUND
(%±SD)

STANDARD ADDITION TECNIQUE
(mean±SD)

TAKEN
(µg/ml)

FOUND
(%±SD)

STANDARD ADDITION TECNIQUE
(mean+_SD)

TAKEN
(µg/ml)

FOUND
(%±SD)

STANDARD ADDITION TECNIQUE
(mean±SD)

Met

5

100.2 ±0.54

100.14±1.09

 

 

 

30

90.4 ±.49

98.7±.4

15

95.89±1.6

102.45±1.4

Pio

7

99.8 ± 0.34

101.3 ± 1.19

10

99.8±0.86

100.9±0.73

 

 

 

 

 

 

Table 4: System suitability testing parameters of TLC densitometric method

MEL

MET

PIO

Parameters

2.09

 

1.44

Selectivity factors

2.4

 

3.4

Resolution

1

4

0.25

Capacity factors

0.77

0.59

0.8

Symmetry factors

Table 5: It shows the statistical comparison of the results obtained by the proposed methods and the established method

Items

HPTLC

Spectrophotometric methods

Reported HPLC method c [26]

 

MET

PIO

MEL

MET

PIO

MET

PIO

Mean

100.1

101.3

99.8

100.46

99.98

101.1667

100.7167

SD

1.2

2.2

1.2

0.75

0.68

1.47196

1.738294

N

6

6

6

6

6

6

6

Variance

1.2

0.5

1.7

0.5

0.1

2.166667

3.021667

Student T test a

0.5

0.3

0.6

2.6

0.01

 

 

F – value b

0.3

0.9

0.16

0.2

0.7

 

 

a figures in parentheses represent the corresponding tabulated values of T at P=0.05
B figures in parentheses represent the corresponding tabulated values of F at P=0.05
C HPLC method : on a Hypersil ODS-C18 column with 5 μm particle size using the mobile phase acetonitrile-water-acetic acid (75 + 25 + 0.3), adjusted to pH 5.5 with liquor ammonia, at a flow rate of 0.5 mL/min [26]
Conclusion
The developed methods have advantages over the published methods in being more simple, rapid, cost effective and data processing steps are not time consuming. Spectrophotometric methods can be regarded as a useful alternative to chromatographic techniques in the routine quality control analysis of pharmaceutical formulations allowing rapid determination at relatively low cost. The advantages of TLC-densitometric method is its ability to determine the studied drugs using one and the same developing system and scanning wavelength, several samples can be run simultaneously using a small quantity of mobile phase unlike HPLC, thus lowering analysis time and cost. The developed methods can be easily adopted for routine quality control analysis of MET and PIO.

The advantages of this spectrophotometric methods are reducing time and cost. Also the proposed TLC–densitometric method has the advantage of being more sensitive than other developed method.
ReferencesTop
  1. Patil Sudarshan S and C Bonde. Development and Validation of analytical method for Simultaneous Estimation of Glibenclamide and Metformin HCl in Bulk and Tablets using UV–visible spectroscopy. International Journal of ChemTech Research. 2009;1(4):905-909.
  2. Lakshmi K, T Rajesh and S Sharma. Simultaneous determination of metformin and pioglitazone by reversed phase HPLC in pharmaceutical dosage forms. International Journal of Pharmacy and Pharmaceutical Sciences. 2009;1(2):162-166.
  3. Hegazy MA, El-Ghobashy MR, Yehia AM, Mostafa AA. Simultaneous determination of metformin hydrochloride and pioglitazone hydrochloride in binary mixture and in their ternary mixture with pioglitazone acid degradate using spectrophotometric and chemometric methods. Drug Test Anal. 2009;1(7):339-349. doi: 10.1002/dta.60
  4. Zarghi A, Foroutan SM, Shafaati A, Khoddam A. Rapid determination of metformin in human plasma using ion-pair HPLC. J Pharm Biomed Anal. 2003;31(1):197-200.
  5. Valentina P, Grigoleto SP, Eunice KK, Eunice EK, Yara PA, KazuoF, et al. HPLC-UV determination of metformin in human plasma for application in pharmacokinetics and bioequivalence studies. Journal of pharmaceutical and biomedical analysis. 2008;46(1):143-147.
  6. Tache F, Victor David, Alexandru Farca, Andrei Medvedovici. HPLC-DAD determination of Metformin in human plasma using derivatization with p-nitrobenzoyl chloride in a biphasic system. Microchemical journal. 2001;68(1):13-19.
  7. Yuen KH and KK Peh. Simple high-performance liquid chromatographic method for the determination of metformin in human plasma. Journal of Chromatography B: Biomedical Sciences and Applications. 1998;710(1):243-246.
  8. Cheng CL and CH Chou. Determination of metformin in human plasma by high-performance liquid chromatography with spectrophotometric detection. J Chromatogr B Biomed Sci Appl. 2001;762(1):51-58.
  9. Huupponen R, Ojala-Karlsson. Determination of metformin in plasma by high-performance liquid chromatography. Journal of Chromatography B: Biomedical Sciences and Applications. 1992;583(2):270-273.
  10. Ross M. Determination of metformin in biological fluids by derivatization followed by high-performance liquid chromatography. J Chromatogr. 1977;133(2):408-411
  11. Hassan SS, Wagiha H Mahmoud, Mohamed AF, Abdel Hammeed M. Determination of metformin in pharmaceutical preparations using potentiometry. spectrofluorimetry and UV–visible spectrophotometry. Analytica chimica acta. 1999;378(1-3):299-311.
  12. Habib I and M Kamel. Near infra-red reflectance spectroscopic determination of metformin in tablets. Talanta. 2003;60(1):185-190. doi: 10.1016/S0039-9140(03)00123-1
  13. Song JZ, Chen HF, Tian SJ, Sun ZP. Determination of metformin in plasma by capillary electrophoresis using field-amplified sample stacking technique. J Chromatogr B Biomed Sci Appl. 1998;708(1-2):277-283.
  14. Hamdan II, Jaber AK, Abushoffa AM. Development and validation of a stability indicating capillary electrophoresis method for the determination of metformin hydrochloride in tablets. J Pharm Biomed Anal. 2010;53(5):1254-1257. doi: 10.1016/j.jpba.2010.03.017
  15. Tůma P. Large volume sample stacking for rapid and sensitive determination of antidiabetic drug metformin in human urine and serum by capillary electrophoresis with contactless conductivity detection. J Chromatogr A. 2014;1345:207-211. doi: 10.1016/j.chroma.2014.04.016
  16. Radhakrishna T, DS Rao and GO Reddy. Determination of pioglitazone hydrochloride in bulk and pharmaceutical formulations by HPLC and MEKC methods. J Pharm Biomed Anal. 2002;29(4):593-607.
  17. Sripalakit P, Neamhom P, Saraphanchotiwitthaya A. High-performance liquid chromatographic method for the determination of pioglitazone in human plasma using ultraviolet detection and its application to a pharmacokinetic study. J Chromatogr B Analyt Technol Biomed Life Sci. 2006;843(2):164-169.
  18. Yamashita K, Murakami H, Okuda T, Motohashi M. High-performance liquid chromatographic determination of pioglitazone and its metabolites in human serum and urine. J Chromatogr B Biomed Appl. 1996;677(1):141-146.
  19. Lin ZJ, Ji W, Desai Krieger D, Shum L. Simultaneous determination of pioglitazone and its two active metabolites in human plasma by LC–MS/MS. J Pharm Biomed Anal. 2003;33(1):101-108.
  20. Calixto LA, PS Bonato. Combination of hollow‐fiber liquid‐phase microextraction and capillary electrophoresis for pioglitazone and its main metabolites determination in rat liver microsomal fraction. Electrophoresis. 2013 ;34(6):862-869. doi: 10.1002/elps.201200430
  21. Shankar MB, Modi VD, Shah DA, Bhatt KK, Mehta RS, Geetha M, Patel BJ. Estimation of pioglitazone hydrochloride and metformin hydrochloride in tablets by derivative spectrophotometry and liquid chromatographic methods. J AOAC Int. 2005;88(4):1167-1172.
  22. Chaturvedi P, R Sharma. Simultaneous spectrophotometric estimation and validation of three component tablet formulation containing pioglitazone hydrochloride, metformin hydrochloride and glibenclamide. Analytical letters. 2008;41(12):2133-2142.
  23. Adhikari L, S Jagadev, S Sahoo, PN Murthy, US Mishra. Devlopement and validation of UV-visible spectrophotometric method for simultaneous determination of Pioglitazone Hydrochloride, Metformin Hydrochloride and glipizide in its bulk and pharmaceutical dosage form (tablet). International Journal of ChemTech Research. 2012;4(2):625-630.
  24. Jain D, Jain S, Jain D, Amin M. Simultaneous estimation of metformin hydrochloride, pioglitazone hydrochloride, and glimepiride by RP-HPLC in tablet formulation. J Chromatogr Sci. 2008;46(6):501-504.
  25. El-Ghobashy M, A Yehia, A Mostafa. Application of membrane-selective electrodes for the determination of pioglitazone hydrochloride in the presence of its acid degradant or metformin hydrochloride in tablets and plasma. Analytical Letters. 2009;42(1):123-140.
  26. Sahoo PK, Sharma R, Chaturvedi SC. Simultaneous estimation of metformin hydrochloride and pioglitazone hydrochloride by RPHPLC method from combined tablet dosage form. Indian J Pharm Sci. 2008;70(3):383-386. doi: 10.4103/0250-474X.43010
  27. Naguib IA, Abdelaleem EA, Zaazaa HE, Draz ME. Simultaneous Determination of Hydrochlorothiazide and Benazepril Hydrochloride or Amiloride Hydrochloride in Presence of Hydrochlorothiazide Impurities: Chlorothiazide and Salamide by HPTLC Method. J Chromatogr Sci. 2015;53(1):183-188. doi: 10.1093/chromsci/bmu016
 
Listing : ICMJE   

Creative Commons License Open Access by Symbiosis is licensed under a Creative Commons Attribution 4.0 Unported License