Temporomandibular Disorders, Non-Carious
Cervical Lesions and Implant Failures: is Occlusion
Guilty or Innocent?
Tzu Hung Lin1, Pei Yi Tsai2, Pei-Ying Lu3 and Yu Chih Chiang3*
1Material and Chemical Research Laboratories, Industrial Technology Research Institute, HsinChu, Taiwan, ROC
2 Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, HsinChu, Taiwan, ROC
3 Division of Restorative and Esthetic Dentistry, School of Dentistry and Graduate Institute of Clinical Dentistry, National Taiwan University and National Taiwan University Hospital, Taipei, Taiwan, ROC
2 Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, HsinChu, Taiwan, ROC
3 Division of Restorative and Esthetic Dentistry, School of Dentistry and Graduate Institute of Clinical Dentistry, National Taiwan University and National Taiwan University Hospital, Taipei, Taiwan, ROC
*Corresponding author: Yu Chih Chiang, Division of Restorative and Esthetic Dentistry, School of Dentistry, National Taiwan University and National
Taiwan University Hospital, 1, Chang-de St., Taipei, Taiwan, E-mail:
@
Received: September 21, 2020; Accepted: September 28, 2020; Published: October 05, 2020
Citation: Tzu Hung Lin, Pei Yi Tsai, Pei Yung Lu and Yu Chih Chiang (2020) The Application of Nano/Micro-CT to Preclinical Dental Research and Dental Device Development. J Dent Oral Disord Ther 8(3): 1- 4 DOI: 10.15226/jdodt.2020.001118
Abstract Top
The application of Micro-Computed Tomography (micro-CT) and
novel Nano-Computed Tomography (nano-CT), 3D X-ray technique to
biomedical research including dental research and dental materials
development are considerable and growing. This technique can
provide high resolution and detailed 3D images for researchers to gain
more insight into their samples nondestructively. The samples remain
incessantly for further mechanical test and histological analysis. In
this article we will highlight the recent applications for dental and
endodontic studies.
IntroductionTop
Computed Tomography (CT) technique is used frequently as
a non-invasive Three-Dimensional (3D) method which can image
internal and external 3D geometry and structure information.
Recent years, they are widely used in many fields, especially
for dental research, orthopedic research, tissue engineering
and the development of biomedical devices. This technique can
investigate the internal 3D feathers without sample destruction
and this character is really important for clinical application.
The market size of CT instrument approached 4 billion in 2017.
For clinical application, doctors use CT technique to diagnose
disease and it plays an important role in orthopaedic and dental
fields. Compared to clinical CT, micro-CT was developed in early
1980s and it has a better spatial resolution. In early 2010s, the
voxel resolution is improved to 5-50 μm [1]. The micro-focus
X-ray source allows for projections rotated through 180-360
degrees scan to produce 3D reconstructed images and perform
3D structures inside or outside the samples. Nowadays, the
evolution of micro-focus and nano-focus X-ray tube in addition
to novel high sensitive detectors make high resolution laboratory
CT systems possible, the voxel resolution can be improved to
sub-μm scale [2]. Combination of micro/nano-CT system with
histology or SEM (Scanning Electron Microscope) is quite popular
in this field especially in bone and dental applications. The most
important advantage of this technique is using this 3D technology
to discover the 3D structure information, pore information, pore
connectivity and osseointegration between implants and bone
in animal models. For orthopaedic research, many researchers
used micro-CT to get 3D information for disease models like
osteoporosis [3], rheumatoid arthritis [4] and osteoarthritis [5].
In this topic, we will introduce how researchers use this novel
technology in preclinical dental research and dental device
development including novel dental implants development,
dentin hypersensitive treatment, pulp damage treatment.
Dental Implant Development
Dental implant treatment is used to help replace a missing tooth. It needs to be successfully fixed in the bone and it is necessary to determine the implant stabilization and osseointegration, the connection between the living bone and the artificially placed implant. Researchers are going to proceed detailed 3D analysis especially for osteointegration during the development of dental implants. Previously, researchers used to use other conventional methods such as histology, Scanning Electron Microscopy (SEM), and Atomic Force Microscopy (AFM) which are available to study the bone–implant interface. Because metal material such as titanium in dental implants/screws may cause scattering problems during 3D scan. Recently, the improved software algorithms and hardware contribute better Signal Noise Ratio (SNR) and solve many image issues like reconstruction artifacts, beam hardening artifacts, reconstruction center errors and metal scattering. For example, we inserted the porous metal implants into rabbits and then use micro-CT to monitor the bone ongrowth, BIC (bone-implant contact) and bone ingrowth on bone/dental implants (Figure1)[6]. Researchers used to combine the internal 3D information with 2D histology and EDS (Energy Dispersive Spectrometer) for material mapping. This action can accelerate the progress of novel dental device development.
Dental Implant Development
Dental implant treatment is used to help replace a missing tooth. It needs to be successfully fixed in the bone and it is necessary to determine the implant stabilization and osseointegration, the connection between the living bone and the artificially placed implant. Researchers are going to proceed detailed 3D analysis especially for osteointegration during the development of dental implants. Previously, researchers used to use other conventional methods such as histology, Scanning Electron Microscopy (SEM), and Atomic Force Microscopy (AFM) which are available to study the bone–implant interface. Because metal material such as titanium in dental implants/screws may cause scattering problems during 3D scan. Recently, the improved software algorithms and hardware contribute better Signal Noise Ratio (SNR) and solve many image issues like reconstruction artifacts, beam hardening artifacts, reconstruction center errors and metal scattering. For example, we inserted the porous metal implants into rabbits and then use micro-CT to monitor the bone ongrowth, BIC (bone-implant contact) and bone ingrowth on bone/dental implants (Figure1)[6]. Researchers used to combine the internal 3D information with 2D histology and EDS (Energy Dispersive Spectrometer) for material mapping. This action can accelerate the progress of novel dental device development.
Figure 1: Micro-CT revealed the BIC (Bone-Implant Contact) in 3D images
Dentin Hypersensitivity Treatment Development
Dentin is a hydrated hard tissue and is the major portion of
the tooth which protects the pulp. Dentin is the substance that
lies beneath the enamel and the cementum in the tooth. Root
sensitivity is a common disease due to gingival recession in
which dentin was directly exposed to oral environment [7]. The
hydrodynamic theory asserts that when dentin is exposed to
thermal, chemical, tactile or evaporative stimuli, the movement
of the fluid within dentinal tubule stimulates the mechanical
receptors which are sensitive to fluid pressure, resulting in
the transmission of the stimuli to the pulpal nerves ultimately
causing the pain response [8].
There are many commercial products to prevent dental hypersensitivity, most of them try to block the dentinal tubule to inhibit the stimuli of oral environment. However, most of them can only superficially cover the surface of dentinal tubule (2-10 μm) and after the daily brushing, chewing or food erosion, the covered material would be lost and dentinal tubule would be exposed again. Researchers are investigating novel biomimetic materials which can be stable in the deep area of the tiny dentinal tubules. To achieve the goal, researchers need to monitor the whole 3D structure of dentinal tubule. SEM analysis showed that the diameter of dentinal tubule of human teeth is about 2.44 – 2.99 μm [9]. Recently, Zanette et al., used the phytography X-ray nano-CT to clearly demonstrate the 3D structure of dentinal tubule with the diameter of 1-2 μm [10]. This size range is a proper target for a high-resolution micro/nano-CT. In order to develop new long-lasting anti-dentin hypersensitive material, we previously used Sub-micron-CT (Bruker Skyscan 1272) combined SEM to display the 3D structure of dentinal tubule and find the developed bioactive calcium phosphate precipitated in dentinal tubule and found that novel mesoporous silica biomaterial derived crystallization blocked the dentinal tubule efficiently with the depth of 40-60 μm (Figure2) [11].
Root Canal Damage Treatment Development
Vital pulp therapy is now considered a pivotal treatment for pulp/root damage due to the development of Minimally Invasive Dentistry (MID), regeneration medicine and novel dental materials. However, we still need to develop the more efficiency and pulp capping material. Novel pulp capping material with growth factor to enhance the recovery of reparative dentin. Pulpotomy in rats is a good animal model for this research. Researchers can use the in vivo micro-CT (Bruker Skyscan 1176) to check the status including volume and calcium content of calcified tissue in rats. We can find that the increase of calcified area in different time periods (Figure 3) [12]. In addition, ex vivo nano-CT (Bruker Skyscan 2211)” can provide nano-scale resolution and better contrast, this character can be used for the development of complex micro-porous scaffold in this field. Researchers using nano-CT with SEM to monitor the 3D pore distribution and structure distribution for novel scaffold investigation (Figure 4) [13].These results showed 3D information of porosity, pore size distribution, closed pores, open pores and pore connectivity. This new scaffold will be used to endodontic therapy and researchers can used the in vivo system for the upcoming animal experiments. This is a good example to combine both high resolution ex vivo nano-CT and in vivo micro-CT
There are many commercial products to prevent dental hypersensitivity, most of them try to block the dentinal tubule to inhibit the stimuli of oral environment. However, most of them can only superficially cover the surface of dentinal tubule (2-10 μm) and after the daily brushing, chewing or food erosion, the covered material would be lost and dentinal tubule would be exposed again. Researchers are investigating novel biomimetic materials which can be stable in the deep area of the tiny dentinal tubules. To achieve the goal, researchers need to monitor the whole 3D structure of dentinal tubule. SEM analysis showed that the diameter of dentinal tubule of human teeth is about 2.44 – 2.99 μm [9]. Recently, Zanette et al., used the phytography X-ray nano-CT to clearly demonstrate the 3D structure of dentinal tubule with the diameter of 1-2 μm [10]. This size range is a proper target for a high-resolution micro/nano-CT. In order to develop new long-lasting anti-dentin hypersensitive material, we previously used Sub-micron-CT (Bruker Skyscan 1272) combined SEM to display the 3D structure of dentinal tubule and find the developed bioactive calcium phosphate precipitated in dentinal tubule and found that novel mesoporous silica biomaterial derived crystallization blocked the dentinal tubule efficiently with the depth of 40-60 μm (Figure2) [11].
Root Canal Damage Treatment Development
Vital pulp therapy is now considered a pivotal treatment for pulp/root damage due to the development of Minimally Invasive Dentistry (MID), regeneration medicine and novel dental materials. However, we still need to develop the more efficiency and pulp capping material. Novel pulp capping material with growth factor to enhance the recovery of reparative dentin. Pulpotomy in rats is a good animal model for this research. Researchers can use the in vivo micro-CT (Bruker Skyscan 1176) to check the status including volume and calcium content of calcified tissue in rats. We can find that the increase of calcified area in different time periods (Figure 3) [12]. In addition, ex vivo nano-CT (Bruker Skyscan 2211)” can provide nano-scale resolution and better contrast, this character can be used for the development of complex micro-porous scaffold in this field. Researchers using nano-CT with SEM to monitor the 3D pore distribution and structure distribution for novel scaffold investigation (Figure 4) [13].These results showed 3D information of porosity, pore size distribution, closed pores, open pores and pore connectivity. This new scaffold will be used to endodontic therapy and researchers can used the in vivo system for the upcoming animal experiments. This is a good example to combine both high resolution ex vivo nano-CT and in vivo micro-CT
Figure 2: Micro-CT images showed the 3D information of crystal columns in dentinal tubules.
Figure 3: In vivo micro-CT showed 3D information of the calcified hard tissue volume and distribution at different time point.
Figure 4:Nano-CT combined SEM showed the detail morphometric information of the pores.
Conclusion Top
Multiscale micro/nano-CT can provide 3D structure
information and 3D analysis, researchers can also perform
histology/SEM/mechanical test after non-destructive CT scan.
Combining this technique with advanced 3D software can help
professional researchers and clinical dentists to overcome the
obstacle and achieve the goal for preclinical dental research and
dental device development.
References
- Swain MV, Jing Xue. State of the Art of Micro-CT Applications in Dental Research. Int J Oral Sci. 2009;1(4):177–188.
- Salarian M, Toyserkani E. The use of nano-computed tomography (nano-CT) in non-destructive testing of metallic parts made by laser powder-bed fusion additive manufacturing. Int J AdvManuf Technol. 2018;98:3147–3153
- Longo AB, Salmon PL, Ward WE. Comparison of ex vivo and in vivo micro‐computed tomography of rat tibia at different scanning settings. J Orthop Res. 2017;35(8):1690-1698.
- Huang C, Chiou CH, Liu SC, Hu SL, Chen Su, et al. Melatonin attenuates TNF‐α and IL‐1β expression in synovial fibroblasts and diminishes cartilage degradation: Implications for the treatment of rheumatoid arthritis. J Pineal Res. 2019;66(3): e12560
- Chien SY, Tsai CH, Liu SC, Huang C, TH Lin, Y Yang, et al. Noggin Inhibits IL-1β and BMP-2 Expression, and Attenuates Cartilage Degeneration and Subchondral Bone Destruction in Experimental Osteoarthritis. Cells. 2020;9(4):927
- Tsai PI, Chen CY, Huang SW, Yang KY, Lin TH, et al. Improvement of bone-tendon fixation by porous titanium interference screw: A rabbit animal model. J Orthop Res. 2018;36(10):2633-2640.
- Nanci Antonio. Ten cate's oral histology-pageburst on vitalsource: development, structure, and function: Elsevier Health Sciences. 2007.
- Brännström M. Dentin sensitivity and aspiration of odontoblasts. J Am Dent Assoc. 1963;66:366-70.
- LopesI MB, Sinhoreti M, Júnior AG, Consani S, Mccabe J. Comparative study of tubular diameter and quantity for human and bovine dentin at different depths. Braz dent j. 2009;20(4):279-283
- Zanette, Enders, Dierolf, Thibault, Gradl, et al. Ptychographic X-ray nanotomography quantifies mineral distributions in human dentine. Scientific Reports. 2015;5.
- Chiang YC, Lin HP, Chang HH, Cheng YW, Tang HY, et al. A mesoporous silica biomaterial for dental biomimetic crystallization. ACS nano. 2014;8:12502-12513.
- Chiang YC, Chang HH, Wong CC, Wang YP, Wang YL, et al. Nanocrystalline calcium sulfate/hydroxyapatite biphasic compound as a TGF-beta1/VEGF reservoir for vital pulp therapy. Dent Mater. 2016;32(10):1197-1208.
- Chiu YR, Hsu YT, Yu Wu, Hung Lin, Yang, et al. Fabrication of Asymmetrical and Gradient Hierarchy Structures of Poly-p-xylylenes on Multiscale Regimes Based on a Vapor-Phase Sublimation and Deposition Process. Chem Mater. 2020;32(3):1120–1130.